Menu
Menu
Close
Product Details

Sensor for household appliance

  • Sensor for household appliance
  • Sensor for Gas stove

    • Sensor for Gas stove

    Feature

    - High heat resistance
    - Long life with unique material composition
    - 90.0% Market share in Japan & Korea

    Application

    - Gas Stove Anti-Dry function
    - Gas Stove Temperature Control

    Specification

    Resistance value R200=1.175kΩ (example)
    B constant R100/200=4500K (example)
    Thermal time constant About 4 sec (Hot plate)
    Operating temperature range -20℃~300℃
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 750VAC for 1sec

    Structures

  • Sensor for Gas stove (For pot-less detection)

    • Sensor for Gas stove (For pot-less detection)

    Feature

    In addition to the functions of the standard type, it can detect the presence or absence of a pot.

    Application

    - Gas Stove Anti-Dry function
    - Gas Stove Temperature Control
    - Detect the presence or absence of a pot

    Specification

    Resistance value R200=1.175kΩ (example)
    B constant R100/200=4500K (example)
    Thermal time constant About 1 sec (Hot plate)
    Operating temperature range -20℃~300℃
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 750VAC for 1sec

    Structures

  • Sensor for Gas stove Grill

    • Sensor for Gas stove Grill

    Feature

    - Can be easily screwed into the grill cabinet and the internal temperature can be measured.
    - Can be used at high temperatures.
    - Black plating type is also available to prevent response fluctuation due to blackening caused by long-term use.

    Application

    Grill internal temperature measurement

    Specification

    Resistance value R200=1.1kΩ (example)
    B constant R100/200=4500K (example)
    Thermal time constant About 90 sec (in still air)
    Operating temperature range -20℃~300℃
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 750VAC for 3sec

    Structures

  • Sensor for IH Cooking Heater

    • Sensor for IH Cooking Heater

    Feature

    - Mounted on the back side of the glass top to measure the temperature of the bottom of the pot.
    - Ceramic case is unaffected by induction heating.

    Application

    Cooking pot bottom temperature detection

    Specification

    Resistance value R100=2.835kΩ (example)
    B constant R0/100=3450K (example)
    Thermal time constant About 3 sec (Hot plate)
    Operating temperature range DC.500V 100MΩ以上
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 1500VAC for 1min

    Structures

  • Sensor for Water heater

    • Sensor for Water heater

    Feature

    - Fast Thermal Response with High Accuracy.
    - High Humidity Resistance Performance.
    - Cost reduction and stable quality by simple structure.

    Application

    - Water Heater
    - Smart Toilet
    - Coffee maker
    - Fuel cell battery

    Application

    Resistance value R40=26.06kΩ (example)
    B constant R0/100=3970K (example)
    Thermal time constant About 0.5-0.8 sec (in water)
    Operating temperature range -30℃~120℃
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 1800VAC for 1sec

    Structures

  • Sensor for Hot water storage tank

    • Sensor for Hot water storage tank

    Feature

    - Easily mounted on the surface of hot water storage tanks and capable of detecting water temperature and water level.
    - The special shape of the screw stopper has a raised portion on its side, which prevents warping due to loading, adheres closely to the heat-sensitive part, and enables stable detection.

    Application

    Detection of water level in hot water storage tank of water heater

    Specification

    Resistance value R45=5.108kΩ (example)
    B constant R0/100=3300K (example)
    Thermal time constant About 4 sec (Hot plate)
    Operating temperature range -30℃~105℃
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 1800VAC for 1sec

    Structures

  • Sensor for Hot water storage tank

    • Sensor for Hot water storage tank

    Feature

    - Attached to the side of the hot water storage tank, hot water temperature and water level can be detected.
    - Depending on the application, downsizing is possible.

    Application

    Detection of water level in hot water storage tank of water heater

    Specification

    Resistance value R25=10kΩ (example)
    B constant R25/50=3950K (example)
    Thermal time constant About 4 sec (in water)
    Operating temperature range -30℃~100℃
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 1200VAC for 1sec

    Structures

  • Sensor for Wiring devices

    • Sensor for Wiring devices

    Feature

    - Compact size allows installation in tight spaces.
    - Highly reliable with high dielectric strength construction.

    Application

    Outlet plug overheat detection

    Specification

    Resistance value R25=10kΩ (example)
    B constant R25/85=3435K (example)
    Thermal time constant About 7 sec (Hot plate)
    Operating temperature range -20℃~150℃
    Insulation resistance ≥100MΩ at 500VDC
    Withstand voltage 1200VAC for 1sec

    Structures

TOP